MARITIME TRAINING

video courtesy of facebook.com/NavyCadetsAUS/

  • Compartment Fire Fighting Simulation

  • Damage Leak Stop Simulation

  • Helo Fire

  • Search & Rescue

  • Breathing Apparatus Training

  • Dynamic Hull Rocking

Ship-Based Fire Fighting Simulator

Gas Diesel Fire Fighting Unit

HMAS Cerberus - School of Ship Safety and Survivability

Royal Australia Navy, Victoria - Australia

Features

  • Diesel and Natural Gas Fuel Fires

  • Rollover fires in the galley and main machine rooms

  • Doors and hatch entry to fire rooms

  • Artificial smoke to all compartments

  • Infrared CCTV & PA sound effects

  • Operation from a control tower

  • Multiple training scenarios

Specifications

Fire Compartments

  • Engine & machine rooms

  • Workshops

  • Galley

Control System

  • Full SCADA control of the unit operation

  • Full view of training rooms through artificial smoke

Control

  • Full SCADA control of the unit operation

  • Full view of training rooms through artificial smoke

Safety

  • Emergency stops in firerooms

  • Control System certified to IEC 61508 - SIL 2

  • Gas controls certified to local and international standards

Ship-Based Damage Control Simulator

Leak Stop Repair Unit

HMAS Cerberus - School of Ship Safety and Survivability

Royal Australia Navy, Victoria - Australia

Features

  • Hull oscillation ±10°

  • High and low-pressure damage points

  • Compartment flooding up to 1.8m

  • Water capture and treatment

  • Watertight doors and hatches

  • CCTV & damage sound effects

  • Casualty power system training

Specifications

Movement

  • Static and dynamic List ± 10°

  • Full oscillation (40° total roll) period less than 1 minute

  • Hydraulic power and actuators supplied by Bosch Rexroth

Water Level

  • Real-time level sensors for each compartment

  • Overflows prevent the maximum water level from being exceeded

Control

  • Full SCADA control of the unit operation

  • Full CCTV view of training rooms

Leaks

  • Modulation of leak intensity

  • Doors and hatches

  • Structural damage

  • Incident damage

  • Pipework and valves

Safety

  • Compartment drainage in 3 minutes.

  • Hull exits to lower and mid-deck platforms

  • Emergency stop located on the hull & platforms

  • Redundant water supply isolation

  • Drain valves are fail-open

Helicopter Fire Fighting Simulator

HELO FFU

HMAS Creswell - School of Ship Safety and Survivability

Jervis Bay Territory - Australia

Features

  • Engine fire

  • Explosion fire

  • Tail Fire

  • Fuel Spill Fire